Catalog Number GSSP40-2424NS, 24 x 24 Inch (in) Size ALTEF Gas Sampling Bag with Screw Cap Combo Valve® with Septum


    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

POLYPROPYLENE SCREW CAP COMBO VALVE WITH REPLACEABLE SEPTUM
  • On/Off valve function with a replaceable septum in a single unit is economical.
  • Lightweight, making it easier to carry in the field and reduces shipping costs.
  • Made of inert polypropylene to ensure purity of sample and non-contamination.
  • Quick, easy opening and closing of valve to save time.
  • Cap stop limits amount cap can be opened to stop leaks from opening cap too far.
  • Visual confirmation that valve is open or closed, prevents accident sample loss.
  • No guessing whether valve is open or closed.
  • Valve Stem is 3/16" OD with tapered outer end for tubing or compression fitting.
  • Replaceable fluoropolymer faced, low bleed septum; allows reuse of valve by replacing inexpensive septum.
  • Designed and Manufactured by Jensen Inert Products specifically for gas sampling applications.
  • Prices include Screw Cap Combo Valve with septum.
  • 3/16" OD stem for use with most 1/4" OD plastic and fluoropolymer tubing.
  • Bags with grommets available.
  • Bags with multiple fittings available.
  • Custom sized bags available.





Specifications  · Note  · Additional Information  · Valve/Fitting Features  · Film Key Features  · Suggestion  · Film Properties  · Film Advantages  · Film Limitations  · Valve/Fitting Benefits

Specifications

Film Material

ALTEF

Capacity

40.0 L

Size

24 x 24 in

Film Thickness

0.003 in

Bags Per Package

5

Valve Stem Diameter

3/16 in

Minimum Order Quantity

5


Note
Valve is inert, industry standard polypropylene.
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I. Dupont



Additional Information
Catalog Number: SEP5007NSCV7010, Fluoropolymer Faced 0.070" Thick Septa, For Screw Cap Valve/10



Valve/Fitting Features
  • On/off valve function with replaceable septum in a single unit.
  • Lightweight.
  • Made of Inert polypropylene.
  • Quick turning screw cap to open and close valve. Cap stop limits amount cap can be opened.
  • Visual confirmation that valve is open or closed.
  • Replaceable fluoropolymer faced, low bleed septum.
  • Designed and manufactured by Jensen Inert Products.




Film Key Features
  • ALTEF is a proprietary fluoropolymer film developed specially for the air sampling market.
  • ALTEF meets or exceeds many of the desired characteristics of Tedlar®.
  • Unlike Tedlar®, ALTEF does not exhibit background levels of DMAC and phenol.
  • ALTEFexhibits similar stability properties as Tedlar® for a wide variety of compounds, including most VOCs.
  • Low VOC and sulfur background levels.
  • Contains no additives, fillers or pigments.
  • Minimal adsorption.
  • Superior storage for organics.
  • Abrasion Resistant.




Suggestion
  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.




Film Properties
  • Developed specifically for gas sampling applications
  • Chemically inert to most acids, aliphatic and aromatic organic compounds, chlorinated solvents, and alcohols
  • Maximum operating temp: 260 ºF
  • ALTEF bags are made of 0.003" thick film.
  • Tensile Strength 6100 psi




Film Advantages
  • Suitable for sampling most VOCs and many sulfur compounds
  • Low VOC background
  • Longer sample storage times than most other bag materials
  • Does not exhibit background levels of DMAC or phenol, as Tedlar® does
  • Lower permeability than Tedlar® to CO2, N2, CH4
  • Superior resistance to solvents




Film Limitations
  • More permeable to most compounds than Tedlar® (0.003" thick versus 0.002" for Tedlar® Bags)
  • Not suitable for sampling ketones and esters in high concentrations (>30 %)
  • Less resistance to UV light than Tedlar®
  • Many sulfur compounds should be analyzed within 24 hours.
  • More expensive than Tedlar®




Valve/Fitting Benefits
  • Economical: Cost savings in manufacturing is passed on to customers. Septum can be changed.
  • Reduces shipping costs. Easier to carry in the field.
  • Ensures purity of sample and non-contamination.
  • Quick, easy opening and closing of valve: saves time. Cap stop leaks from opening cap too far.
  • Prevents accidental sample loss. No guessing whether valve is open or closed.
  • Allows reuse of valve by replacing inexpensive septum.
  • Designed specifically for gas sampling applications.
  • Economical: Cost savings in manufacturing is passed on to customers.
  • Reduces shipping costs. Easier to carry multiple bags into the field.
  • Ensures purity of sample and non contamination.
  • Quick, easy opening and closing of valve (< 1 second).
  • Faster than "twist action" valves.
  • Locked position is easy to verify visually, and prevents accidental sample loss during shipment. Virtually impossible to open or close valve to far.
  • Septum does not come into contact with sample inside bag. Septum allows repeated punctures with syringes without leakage. Ultra low bleed silicone prevents contamination.
  • Designed specifically for gas sampling applications.




 DOWNLOADS 

Gas Sampling Bag Product Sheet
(PDF, 578KB)

Fitting Features and Benefits
(PDF, 755KB)



Home | About Us | Technical Info | Tradeshows | Product News | Contact Us

Jensen Inert Products • 3773 NW 126th Ave. Building 1 • Coral Springs, Florida 33065
Toll Free: 1-800-446-3781 • Tel: 954-344-2006 • Fax: 954-344-2008
Email: jensen@jenseninert.com

At Jensen Inert Products customer service and satisfaction are our main objectives; therefore, if we can be of further assistance, please feel free to contact us:

Tedlar® is a registered trademark of E.I. DuPont.