 All Categories    ALTEF Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem
Products of Fluoropolymers
& Other Non-Contaminating Materials
All Categories > Bags, Gas and Liquid Sampling > ALTEF Gas Sampling Bags > ALTEF Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem > Catalog Number GSS1000-0610J  

Catalog Number GSS1000-0610J, 6 x 10 Inch (in) Size ALTEF Gas Sampling Bag with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem


    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

NICKEL PLATED HR® ON/OFF VALVE WITH 1/4" DIAMETER BARBED STEM
  • Nickel Plated to resist damage from most aggressive chemicals.
  • 1/4" Barbed Stem for attaching tubing, helps keep tubing in place.
  • Leak resistant seal in closed position, prevents sample loss. However, when stem is not closed, sample air passes into the ambient air outside valve.
  • Prices include Nickel Plated HR® ON/OFF Valve.
  • Use 3/16 ID tubing on stem.
  • Bags with grommets available.
  • Bags with multiple fittings available.
  • Custom sized bags available.





Specifications  · Note  · Additional Information  · Valve/Fitting Features  · Film Key Features  · Suggestion  · Film Properties  · Film Advantages  · Film Limitations  · Valve/Fitting Benefits

Specifications

Film Material

ALTEF

Capacity

1.2 L

Size

6 x 10 in

Film Thickness

0.003 in

Bags Per Package

10

Valve Stem Diameter

1/4 in Barbed

Use with Tubing Size (ID)

3/16 in

Minimum Order Quantity

10


Note
Valve is Nickel Plated
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I. Dupont



Additional Information
ALTEF is a proprietary fluoropolymer film developed specially for the air sampling market. ALTEF meets or exceeds many of the desired characteristics of Tedlar®.
  • Unlike Tedlar®, ALTEF does not exhibit background levels of DMAC and phenol.
  • Low VOC and sulfur background levels.
  • Similar stability properties as Tedlar® for a wide variety of compounds, including most VOCs.
  • Developed as an alternative to Tedlar® film for most gas sampling applications.
  • Contains no additives, fillers or pigments.
  • Choice of ten fitting options.
  • Minimal adsorption.
  • Superior storage for organics.
  • Inherently pure.
ALTEF is not recommended for ketones or esters in high concentrations (>30%)
ALTEF is not suitable for storing H2S.
Our Multi-Layer Foil bags are the best choice for collecting and storing H2S.



Valve/Fitting Features
  • Nickel Plated
  • Barbed stem for attaching tubing.
  • Leak resistant seal in closed position.




Film Key Features
  • ALTEF is a proprietary fluoropolymer film developed specially for the air sampling market.
  • ALTEF meets or exceeds many of the desired characteristics of Tedlar®.
  • Unlike Tedlar®, ALTEF does not exhibit background levels of DMAC and phenol.
  • ALTEFexhibits similar stability properties as Tedlar® for a wide variety of compounds, including most VOCs.
  • Low VOC and sulfur background levels.
  • Contains no additives, fillers or pigments.
  • Minimal adsorption.
  • Superior storage for organics.
  • Abrasion Resistant.




Suggestion
  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.




Film Properties
  • Developed specifically for gas sampling applications
  • Chemically inert to most acids, aliphatic and aromatic organic compounds, chlorinated solvents, and alcohols
  • Maximum operating temp: 260 ºF
  • ALTEF bags are made of 0.003" thick film.
  • Tensile Strength 6100 psi




Film Advantages
  • Suitable for sampling most VOCs and many sulfur compounds
  • Low VOC background
  • Longer sample storage times than most other bag materials
  • Does not exhibit background levels of DMAC or phenol, as Tedlar® does
  • Lower permeability than Tedlar® to CO2, N2, CH4
  • Superior resistance to solvents




Film Limitations
  • More permeable to most compounds than Tedlar® (0.003" thick versus 0.002" for Tedlar® Bags)
  • Not suitable for sampling ketones and esters in high concentrations (>30 %)
  • Less resistance to UV light than Tedlar®
  • Many sulfur compounds should be analyzed within 24 hours.
  • More expensive than Tedlar®




Valve/Fitting Benefits
  • Resists damage from most aggressive chemicals.
  • Helps hold tubing in place.
  • Prevents sample loss in closed position. However, when stem is not closed, sample air passes into ambient air outside valve.




 MORE IMAGES 

·  Tedlar® Gas Sampling Bag with On/Off Valve

·  HR


 DOWNLOADS 

Gas Sampling Bag Product Sheet
(PDF, 578KB)

Fitting Features and Benefits
(PDF, 755KB)



Home | About Us | Technical Info | Tradeshows | Product News | Contact Us

Jensen Inert Products • 3773 NW 126th Ave. Building 1 • Coral Springs, Florida 33065
Toll Free: 1-800-446-3781 • Tel: 954-344-2006 • Fax: 954-344-2008
Email: jensen@jenseninert.com

At Jensen Inert Products customer service and satisfaction are our main objectives; therefore, if we can be of further assistance, please feel free to contact us:

Tedlar® is a registered trademark of E.I. DuPont.