PRODUCTS:

Bailers

Bottles, PFA, FEP, and PTFE

Cap Liners, TFE

Check/ Foot Valves, TFE

Filters, Inline, Syringe, Capsule

Gas Sampling Bags

Gloves, Nitrile

Labware

Liquid Sampling Bags/Liners

Rods, TFE

Sheets, TFE

Soil Sampling Syringes

Stirrer Magnets & Accessories

Surface Protector, Rolls

Transfer Cap Assemblies, PFA

Tubing

Join our Mailing List

* indicates required

Close

 

Search Catalog
      GO   
 All Categories    Tedlar® Gas Sampling Bags with Stainless Steel Push/Pull Valve and Separate Stainless Steel Septum Fitting with Replaceable Septum
Products of Fluoropolymers
& Other Non-Contaminating Materials
All Categories > Bags, Gas and Liquid Sampling > Tedlar® Gas Sampling Bags > Tedlar® Gas Sampling Bags with Stainless Steel Push/Pull Valve and Separate Stainless Steel Septum Fitting with Replaceable Septum > Catalog Number GSTSSFP-0909  

Catalog Number GSTSSFP-0909, 9 x 9 Inch (in) Size Tedlar® Gas Sampling Bag with Stainless Steel Push/Pull Valve and Separate Stainless Steel Septum Fitting with Replaceable Septum


    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

STAINLESS STEEL PUSH/PULL VALVE AND SEPARATE STAINLESS STEEL SEPTUM FITTING WITH REPLACEABLE SEPTUM
  • This combination of fitting and valve allows for use of Push/Pull valve for tubing and a separate fitting for septum use.
  • Stainless Steel construction provides durability and ability to withstand use in austere sampling conditions.
  • Replaceable fluoropolymer faced septum, allows repeated punctures with common lab syringes.
  • Septum fitting allows reuse of valve by only replacing septum
  • Push/Pull (On/Off) valve stem for quick, easy opening and closing of valve
  • 3/16" diameter Stainless Steel stem
  • Prices include Stainless Steel Push/Pull valve and separate Stainless Steel Septum fitting
  • Bags with grommets available.
  • Bags with multiple fittings available.
  • Custom sized bags available.





Specifications  · Note  · Additional Information  · Valve/Fitting Features  · Film Key Features  · Suggestion  · Film Properties  · Film Advantages  · Film Limitations  · Valve/Fitting Benefits

Specifications

Film Material

Tedlar®

Capacity

2.0 L

Size

9 x 9 in

Film Thickness

0.002 in

Bags Per Package

10

Use with Tubing Size (ID)

3/16 in

Minimum Order Quantity

10


Note
Valve and Fitting is Stainless Steel.
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I. Dupont



Additional Information
Catalog No. SEP-9010-TCLP-10, Replacement Septa for Stainless Steel Fitting, 10 per pack



Valve/Fitting Features
  • Stainless Steel construction provides durability and ability to withstand use in austere sampling conditions.
  • Stainless Steel valve body and nut
  • 3/16" OD Stainless Steel stem
  • Thumbscrew to lock valve in open or closed position
  • Replaceable fluoropolymer faced septum, allows repeated punctures with common lab syringes.
  • Septum fitting allows reuse of valve by only replacing septum




Film Key Features
Tedlar® film has very low gas permeation levels for most compounds, and high tensile strength. Bags resist puncture in the field. 2 mil Tedlar® film is an economical alternative to FEP bags. Tedlar® is much less permeable than FEP and is unaffected by the chemical components of gases generally sampled, like carbon monoxide, sulfur dioxide, hydrogen sulfide, radon and mercaptans. Continuous use temperature from -98 to 400 ºF (temperature limit depends on fittings used). Required for many EPA testing methods.



Suggestion
  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.




Film Properties
  • Low gas permeation levels - Most gases
  • High tensile strength
  • Withstands temperatures up to 400 ºF
  • Unaffected by the chemical components of gases commonly sampled, like carbon monoxide, sulfur dioxide, hydrogen sulfide, radon, and mercaptons
  • Tensile Strength 8000 psi




Film Advantages
  • Less permeable than FEP, PFA, and TFM
  • Bags resist puncture in the field
  • Less expensive than FEP, PFA, and TFM film
  • Recommended in many EPA testing methods




Film Limitations
  • Exhibits background levels of DMAC and phenol
  • High permeation rate for CO2
  • Relatively high permeation rate for O2
  • *NOTE: We offer bags specially conditioned to remove DMAC and phenol from Tedlar®




Valve/Fitting Benefits
  • Stainless Steel construction provides durability and ability to withstand use in austere sampling conditions.
  • Thumbscrew to lock valve in open or closed position
  • Replaceable fluoropolymer faced septum, allows repeated punctures with common lab syringes.




 MORE IMAGES 

·  Stainless Steel Combo Valve


 DOWNLOADS 

Gas Sampling Bag Product Sheet
(PDF, 578KB)

Fitting Features and Benefits
(PDF, 755KB)



Home | About Us | Technical Info | Tradeshows | Product News | Contact Us

Jensen Inert Products • 3773 NW 126th Ave. Building 1 • Coral Springs, Florida 33065
Toll Free: 1-800-446-3781 • Tel: 954-344-2006 • Fax: 954-344-2008
Email: jensen@jenseninert.com

At Jensen Inert Products customer service and satisfaction are our main objectives; therefore, if we can be of further assistance, please feel free to contact us:

Tedlar® is a registered trademark of E.I. DuPont.