 All Categories    Multi-Layer Foil Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem
Products of Fluoropolymers
& Other Non-Contaminating Materials
All Categories > Bags, Gas and Liquid Sampling > Multi-Layer Foil Gas Sampling Bags > Multi-Layer Foil Gas Sampling Bags with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem > Catalog Number GSA1000-1221J  

Catalog Number GSA1000-1221J, 12 x 21 Inch (in) Size Multi-Layer Foil Bag with Nickel Plated HR® ON/OFF Valve with 1/4'' Diameter Barbed Stem


    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

NICKEL PLATED HR® ON/OFF VALVE WITH 1/4" DIAMETER BARBED STEM
  • Nickel Plated to resist damage from most aggressive chemicals.
  • 1/4" Barbed Stem for attaching tubing, helps keep tubing in place.
  • Leak resistant seal in closed position, prevents sample loss. However, when stem is not closed, sample air passes into the ambient air outside valve.
  • Prices include Nickel Plated HR® ON/OFF Valve.
  • Use 3/16 ID tubing on stem.
  • Bags with grommets available.
  • Bags with multiple fittings available.
  • Custom sized bags available.





Specifications  · Note  · Valve/Fitting Features  · Film Key Features  · Suggestion  · Film Properties  · Film Advantages  · Film Limitations  · Valve/Fitting Benefits

Specifications

Film Material

MULTI-LAYER FOIL

Capacity

12.0 L

Size

12 x 21 in

Film Thickness

0.0046 in

Bags Per Package

5

Valve Stem Diameter

1/4 in Barbed

Use with Tubing Size (ID)

3/16 in

Minimum Order Quantity

5


Note
Valve is Nickel Plated
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I. Dupont



Valve/Fitting Features
  • Nickel Plated
  • Barbed stem for attaching tubing.
  • Leak resistant seal in closed position.




Film Key Features
  • Our Multi-Layer Foil bags are the best choice for collecting and storing H2S.
  • Ideal for sampling and storing for low molecular weight compounds such as Methane, CO, CO2, Hydrogen, and inert gases which are not stable in Tedlar®, ALTEF, or FEP.
  • Water and vapor proof, these opaque, flexible bags protect light sensitive compounds.
  • They provide up to 5 day sample stability for many VOCs, with minimal adsorption.




Suggestion
  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.




Film Properties
  • Ideal for collecting low molecular weight compounds such as: CH4, H2S, CO, and CO2
  • Foil layers provide very low permeability and complete moisture barrier
  • Maximum operating temperature: 190 ºF
  • Opaqueness protects samples from ultraviolet light




Film Advantages
  • The only bag material that adequately holds H2S for long periods (>5 to 7 days)
  • Ideal for collecting low molecular weight compounds
  • Sample stability for up to 5 days for most compounds
  • Very low permeability to O2, CO2
  • Good VOC stability
  • Less expensive than Tedlar® and ALTEF




Film Limitations
  • Not recommended for collecting low ppm to high ppb VOC's due to background levels from bag materials
  • Recommend analyzing within 48 hours after collection for methane, hydrogen sulfide, carbon monoxide and carbon dioxide




Valve/Fitting Benefits
  • Resists damage from most aggressive chemicals.
  • Helps hold tubing in place.
  • Prevents sample loss in closed position. However, when stem is not closed, sample air passes into ambient air outside valve.




 MORE IMAGES 

·  HR


 DOWNLOADS 

Gas Sampling Bag Product Sheet
(PDF, 578KB)

Fitting Features and Benefits
(PDF, 755KB)



Home | About Us | Technical Info | Tradeshows | Product News | Contact Us

Jensen Inert Products • 3773 NW 126th Ave. Building 1 • Coral Springs, Florida 33065
Toll Free: 1-800-446-3781 • Tel: 954-344-2006 • Fax: 954-344-2008
Email: jensen@jenseninert.com

At Jensen Inert Products customer service and satisfaction are our main objectives; therefore, if we can be of further assistance, please feel free to contact us:

Tedlar® is a registered trademark of E.I. DuPont.