PFA FITTING FOR 1/4" OD TUBING OR SEPTUM
  • PFA Fluoropolymer construction so sample only comes into contact with high purity, inert PFA, the ultimate in chemical resistance and non-contaminating material
  • Option of cap for tubing to allow attachment of tubing or cap with septum to allow syringe sample extraction by changing caps.
  • Replaceable fluoropolymer faced septum with large area, allows repeated punctures with common lab syringes.
  • Allows reuse of valve by only replacing septum
  • Prices include PFA fitting for 1/4” OD tubing
  • Bags with grommets available.
  • Bags with multiple fittings available.
  • Custom sized bags available.
Unit of Measure

Specifications

Film Material

N/A MULTI-LAYER FOIL

Capacity

N/A 56.0 L

Size

N/A 24 x 30 in

Film Thickness

N/A 0.0046 in

Bags Per Package

N/A 3

Use with Tubing Size (OD)

N/A 1/4 in

Minimum Order Quantity

N/A 3

Note

N/A Valve is PFA fluoropolymer.
Locking Combo® is a registered trademark of Jensen Inert Products, Inc.
Swagelok® is a register trademark of Swagelok, Inc.
Jaco® is a registered trademark of Jaco Manufacturing, Inc.
HR® is a registered trademark of Halkey Roberts, Inc.
Tedlar® is a registered trademark of E.I. Dupont

Additional Information

N/A Catalog No. CAP-14-PS, Extra Cap with Septum for PFA fitting, Each

Valve/Fitting Features

N/A

  • PFA fluoropolymer construction
  • Option of cap for tubing, or cap with septum.
  • Compression ferrule secures tubing onto fitting.
  • Replaceable fluoropolymer faced septum with large area.

Film Key Features

N/A

  • Our Multi-Layer Foil bags are the best choice for collecting and storing H2S.
  • Ideal for sampling and storing for low molecular weight compounds such as Methane, CO, CO2, Hydrogen, and inert gases which are not stable in Tedlar®, ALTEF, or FEP.
  • Water and vapor proof, these opaque, flexible bags protect light sensitive compounds.
  • They provide up to 5 day sample stability for many VOCs, with minimal adsorption.

Suggestion

N/A

  • Before use, thoroughly flush bags with ultra-pure nitrogen or zero air
  • During sampling, Fluoropolymer tubing and Fluoropolymer faced septums must be used in order to prevent sample loss.
  • Bags should not be filled to more than 80% of their maximum volume.
  • Charcoal (Black) Tedlar® bags should be used when sampling light sensitive compounds
  • Do not store compounds in bags long term due to the possibility that chemicals may adsorb onto the bag surface.
  • Bags should not be used to collect reactive or unstable compounds.
  • When shipping bags, do not air-ship unless the bags are stored in a pressurized area.

Film Properties

N/A

  • Ideal for collecting low molecular weight compounds such as: CH4, H2S, CO, and CO2
  • Foil layers provide very low permeability and complete moisture barrier
  • Maximum operating temperature: 190 ºF
  • Opaqueness protects samples from ultraviolet light

Film Advantages

N/A

  • The only bag material that adequately holds H2S for long periods (>5 to 7 days)
  • Ideal for collecting low molecular weight compounds
  • Sample stability for up to 5 days for most compounds
  • Very low permeability to O2, CO2
  • Good VOC stability
  • Less expensive than Tedlar® and ALTEF

Film Limitations

N/A

  • Not recommended for collecting low ppm to high ppb VOC's due to background levels from bag materials
  • Recommend analyzing within 48 hours after collection for methane, hydrogen sulfide, carbon monoxide and carbon dioxide

Valve/Fitting Benefits

N/A

  • Sample only comes into contact with high purity, inert fluoropolymer PFA, the ultimate in chemical resistance and non-contaminating material.
  • Allows attachment of tubing or syringe sample extraction by changing caps
  • Superior grip compared to metal fittings.
  • Allows repeated punctures with common lab syringes.
  • Allows reuse of valve by only replacing septum.